PTM(4D) | Devices | PTM(4D) |
ptm
, pts
—
STREAMS pseudo-terminal manager and subsidiary
drivers
/dev/ptmx
/dev/pts/*
The pseudo-terminal subsystem simulates a terminal connection,
where the manager side represents the terminal and the subsidiary represents
the user process's special device end point. The manager device is set up as
a cloned device where its major device number is the major for the clone
device and its minor device number is the major for the
ptm
driver; see CLONE_DEV
in
ddi_create_minor_node(9F).
There are no nodes in the file system for manager devices. The
manager pseudo driver is opened using the
open(2) system call with
/dev/ptmx as the device parameter. The clone open
finds the next available minor device for the ptm
major device.
A manager device is only available if it and its corresponding subsidiary device are not already open. Only one open is allowed on a manager device. Multiple opens are allowed on the subsidiary device.
When the manager device is opened, the corresponding subsidiary device is automatically locked out. No user may open the subsidiary device until its permissions are adjusted and the device is unlocked by calling the functions grantpt(3C) and unlockpt(3C). The user can then invoke the open(2) system call with the device name returned by the ptsname(3C) function.
After both the manager and subsidiary have been opened, the user has two file descriptors which are the end points of a full duplex connection composed of two streams which are automatically connected at the manager and subsidiary drivers. The user may then push modules onto either side of the stream pair. Unless compiled in XPG4v2 mode (see XPG4v2 MODE), the consumer needs to push the ptem(4M) and ldterm(4M) modules onto the subsidiary device to get terminal semantics.
The manager and subsidiary drivers pass all messages to their
adjacent queues. Only the M_FLUSH
needs some
processing. Because the read queue of one side is connected to the write
queue of the other, the FLUSHR
flag is changed to
the FLUSHW
flag and vice versa.
When the manager device is closed, an
M_HANGUP
message is sent to the subsidiary device
which will render the device unusable. The process on the subsidiary side
gets an EIO
error when attempting to write on that
stream, but it will be able to read any data remaining on the stream head
read queue. When all the data has been read,
read(2) returns 0
indicating that the stream can no longer be used.
On the last close of the subsidiary device, a 0-length message is sent to the manager device. When the application on the manager side issues a read(2) or getmsg(2) and 0 is returned, the user of the manager device decides whether to issue a close(2) that dismantles the entire pseudo-terminal. If the manager device is not closed, the pseudo-terminal will be available to another user to open the subsidiary device.
Since 0-length messages are used to indicate that the process on the subsidiary side has closed, and should be interpreted that way by the process on the manager side, applications on the subsidiary side should not write 0-length messages. Unless the application is compiled in XPG4v2 mode (see XPG4v2 MODE), then any 0-length messages written to the subsidiary device will be discarded by the ptem(4M) module.
If O_NONBLOCK
or
O_NDELAY
is set on the manager side:
EAGAIN
if no
data is availableEAGAIN
if there is internal flow controlStandard STREAMS system calls can access pseudo-terminal devices.
The subsidiary devices support the O_NDELAY
and
O_NONBLOCK
flags.
XPG4v2 requires that subsidiary pseudo-terminal devices provide the process with an interface that is identical to the terminal interface, without needing to explicitly push any modules to achieve this. It also requires that 0-length messages written on the subsidiary device will be propagated to the manager device.
Experience has shown that most software does not expect subsidiary pseudo-terminal devices to operate in this manner. This XPG4v2-compliant behaviour is only enabled in XPG4v2/SUS (see standards(7)) mode.
The manager driver provides several ioctls to support the grantpt(3C), unlockpt(3C), and ptsname(3C) functions:
Example 1 Opening the manager and subsidiary device for a pseudo-terminal.
#include <stdlib.h> #include <sys/types.h> #include <sys/stat.h> #include <unistd.h> #include <stropts.h> #include <fcntl.h> #include <err.h> ... int fdm, fds; char *subsidiaryname; ... /* * NOTE: Portable applications should use posix_openpt(3C) here: */ if ((fdm = open("/dev/ptmx", O_RDWR | O_NOCTTY)) < 0) { err(1, "open manager"); } if (grantpt(fdm) != 0 || unlockpt(fdm) != 0 || (subsidiaryname = ptsname(fdm)) == NULL) { close(fdm); err(1, "locate subsidiary"); } if ((fds = open(subsidiaryname, O_RDWR | O_NOCTTY)) < 0) { close(fdm); err(1, "open subsidiary"); } if (ioctl(fds, I_PUSH, "ptem") != 0 || ioctl(fds, I_PUSH, "ldterm") != 0) { close(fds); close(fdm); err(1, "push modules"); }
close(2), getmsg(2), open(2), read(2), grantpt(3C), posix_openpt(3C), ptsname(3C), unlockpt(3C), ldterm(4M), pckt(4M), ptem(4M), standards(7), ddi_create_minor_node(9F)